NANOVIP® CUBE™ is a modern, powerful, S-Class portable network analyzer developed for professional analysis of consumption and power quality of the most complex electrical networks.
It can be used on single-phase, two-phase, three-phase (balanced and unbalanced) networks, low and medium voltage.
The advanced features and analysis software supplied makes it a suitable tool to the most demanding professional needs.
Measurement precision,
powerfull analisys
powerfull analisys
- Can work on networks: single-phase, two-phase, three-phase balanced with or without neutral, three-phase unbalanced with or without neutral
- Full traditional energy analysis (V, I, P, Q, S, F, PF, THD%, instantaneous values / minimum / maximum / average, energy meters absorbed and generated both three-phase for each phase).
- Analysis of power quality parameters
- The current and voltage harmonics for each phase and for the neutral up to 50°
- Imbalance of power phases
- Network outages, surges, sags
- Conformance testing to EN 50160
- Real measurement of the neutral current
- Display of the waveforms of currents and voltages
- 4 tariff bands setting with the related costs display
- Configuration and display of alarms on sizes 20 and settable
- Display of the time course of selectable parameters (trend)
- Automatic check of the correct connection of the implant tool
- Realization of long-term measurement campaigns (over 24 independently, unlimited if connected to the network)
- Multilanguage
- Customizable display, choosing which values display in rotation in the lower part and rotating it 90 ° in relation to the comfort of reading
Fields of use
The NanoVIP3 is a handy tool, compact and light aimed at both those who want to work on their equipment than with industry professionals who need detailed and accurate analysis of power quality; NANOVIP allows in an easy and intuitive way:
- to control the loads, consumption and the associated network costs
- check in service the correct dimensioning of plants
- to prevent the risk for overheating and insulation failures due to high harmonic content
- risolvere correct the power factor correction problems
- Identify and eliminate load peaks and exceed power in order also to reduce the bargaining power commitment
- check and evaluate the returns of UPS, AC / DC measurements
- Measure signals for non-symmetric PWM control of inverter
- Identify the presence of harmonics, outages, overloads or potentially harmful voltage dips for machinery and equipment
- Intercept fluctuations and rapid changes in current and voltage signals
- Measure the inrush currents of motors and electrical machinery
Brochure NanoVIP® CUBE™ 500 kb 1450 downloads
Two channels Power Quality analyzer for monophase, threephase balanced and unbalanced...Standard | IEC61000-4-30 Class S |
Dimensions | 203x116x53mm |
Safety | 600V CAT III |
Protection degree | IP30 |
Weight | 580g. |
Display type | LCD dot matrix with backlight |
Languages | English- Spanish – Italian – German – French |
Communication | USB to PC |
Onboard memory | 64kB |
External memory | Micro SD (4GB supplied) |
Working temperature range | from -10 to +55 °C |
Umidity | Max 95% |
External power supply | Wall-plug switching, input 100-240VAC ±10% 47-63Hz, changeable plug; output 7,5VDC – 12W |
Battery | 4 x AA MiMh 2100mAh |
Autonomy | >24h |
Single phase/Double phase networks | yes |
Three phase 4 wires, balanced networks | yes |
Three phase 3 wires, balanced networks | yes |
Three phase 4 wires, unbalanced networks | yes |
Three phase 3 wires, unbalanced networks | yes |
Power analisys | V, I, P, Q, S, F, PF, THD(V)%, THD(I)%, cosj, j, peaks, min, max, mid, max. demand, ecc. |
Counters | kWh, kVArh, kVAh (used and generated) |
Waves shape | V e I |
Harmonics | Values and spectrum up to 50° |
Sags | Dips, swells and net interruption |
Transitory | Overcurrent and overtension |
Test EN 50160 | yes |
Starting currents | yes |
Measurements in DC | yes |
K factor | Up to 25° |
Alarms | Video |
Alarms logs | 5 on video |
Hourly tarifs | up to 4 |
Consumption costs | yes |
Measurement campaign | Unlimited, up to SD completition |
Display data refres | 1 sec. |
Voltage (TRMS) | 4 input channels (3 + common neutral + 1 auxiliary) |
Current (TRMS) | 5 input channels |
Power | Active, reactive and apparent. Single phase and total |
Energy counters | kWh, kvarh, kVAh |
Harmonics analisys | Up to 50° |
EN50160 analisys | from 500mS up |
Transitional analisys | Overcurrent, overvoltage and starting currents |
CE conformity | 93/68/CEE (B.T. electrical materials); |
89/336/CEE e 2004/108/CE (EMC) | |
2006/95/CE – 72/23/CEE (LVD – Low voltages); | |
2002/95/CE (RoHS – Dangerous materials restrictions); | |
2002/96/CE e 2003/108/CE (WEEE/RAEE – Wasted electrical and electronics materials). | |
Safety | EN 61010-1 |
EMC | EN 61326 |
EN 61326/A1 | |
EN 61326/A2 | |
EN 61326/A3 | |
Temperature | IEC 60068-2-1 (working) |
IEC 60068-2-2 (storage) | |
Vibrations | IEC 60068-2-6 |
Umidity | IEC 60068-2-30 (umidity) |
Overload | IEC 60947-1 |
4NAN3N | NANOVIP/CUBE WITHOUT CLAMPS |
4NAN3 | NANOVIP/CUBE WITH 3xNANOFLEX CLAMP 400mm 3kA |
4NAN3A | NANOVIP/CUBE WITH 3xCLAMP CT 200A/1VAC |
4NAN3B | NANOVIP/CUBE WITH CLAMPS 3x200A + 3x3kA |
4NAN3C | NANOVIP/CUBE WITH CLAMPS 3x5A + 3x200A + 3x1000A |
PART | Quantity | Standard/Option |
NanoVIP CUBE | 1 | Standard |
Battery pack | 1 | Standard |
Voltage cables | 4 | Standard |
Crocodiles | 4 | Standard |
mSD 4Gb | 1 | Standard |
mSD adaptor | 1 | Standard |
External power supply + adapters | 1 | Standard |
Bag | 1 | Standard |
Carton box | 1 | Standard |
Calibration certificate | 1 | Standard |
AC Current probes | 3 or more | Option – According to package |
DC Current clamp | 1 or more | Option – According to package |