Solar Measurement
NANOVIP® DS™
Remote solar device
Portable MRH™ remote solar analyzer
NANOVIP® DS™ is a remote measuring device for solar panels and solar strings to be connected to an heterogeneous (or not) MRH™ measurement network; it measure all the critical parameter of a single or multiple set of solar panels and send them to a NANOVIP® QUADRA™ master device that will assemble all network parameters.
NANOVIP® DS™ is fully driven by a NANOVIP® QUADRA™ master analyzer and an MRH™ network can include up to 5 NANOVIP® DS™ devices wireless connected.
When DS is linked to an MRH network, all data are available on its display as well as they can be red in realtime from the NANOVIP® QUADRA™ Master device.
Extreme easy to use and setup because it just require to be assigned with a role in the network, then the NANOVIP® QUADRA™ master analyzer will set network parameters accordingly.
Spread solar measures
- Self setting wireless network connection
- Max indoor point to point distance: 60m
- Max outdoor point to point distance: 600m
- Temperatures, irradiations and DC data for each panel or string of panel
- Possible to differentiate test result per each group of panels
- Can measure heterogeneous energies and power: solar, elevtrical loads, generators, storage systsems, multiple grid connections, eolic, UPS, inverters etc
- Realtime data available set by set on QUADRA master device
- Multilanguage
- Customizable display, choosing which values display in rotation in the lower part and rotating it 90 ° in relation to the comfort of reading
Fields of use
NANOVIP® DS™ is an high-performance device aimed to measure and test solar sets within an MRH measuring network.
Thanks to its flexible MRH™ technology it can:
- measure and store local ambient and panels temperatures
- measure and store local solar irradiation
- measure and store local wind speed (anemometer is option)
- measure DC generated voltage, current, energy and power
- calculate local efficiency parameter of the single panels or string of panels
- send realtime data to NANOVIP® QUADRA™ master device
- performe single set CEI 8225 test
Standard | IEC61000-4-30 Class S |
Dimensions | 203x116x53mm |
Safety | 600V CAT III |
Protection degree | IP30 |
Weight | 580g. |
Display type | LCD dot matrix with backlight |
Communication | USB to PC, wireless to/from devices |
Onboard memory | 64kB |
External memory | Micro SD (4GB supplied) |
MRH master operating mode | no |
MRH client operating mode | yes |
Standalone | no |
Single point monitoring | yes |
AC measurements | no |
DC measurements | yes |
Solar measurements | yes |
Solar panel and strings test CEI 8225 | yes |
Multilines solar system test CEI 8225 | yes |
Solar realtime measurements | yes |
Solarmeter interface | yes |
Temperatures interface | yes |
Wind speed interface | yes |
General transducers interface | no |
Harmonics | no |
Transients | no |
Inrush | no |
Wave form | no |
Counters | yes |
Alarms | no |
Active, Reactive and Apparent P, E | no |
Tariffs | no |
EN50160 test | no |
QUADRA Studio software | included |
Indoor wireless point to point distance | 60m |
Outdoor wireless point to point distance | 600m |
Working temperature range | from -10 to +55 °C |
Umidity | Max 95% |
External power supply | Wall-plug switching, input 100-240VAC ±10% 47-63Hz, changeable plug; output 7,5VDC – 12W |
Battery | 4 x AA MiMh 2100mAh |
Autonomy | >24h |
Languages | English- Spanish – Italian – German – French |
MRH technology | yes |
Standalone mode | no |
Single phase/Double phase networks | no |
Three phase 4 wires, balanced networks | no |
Three phase 3 wires, balanced networks | no |
Three phase 4 wires, unbalanced networks | no |
Three phase 3 wires, unbalanced networks | no |
Solar measurements | yes |
Power analisys | V, I, P |
Counters | kWh, |
Waves shape | V e I |
Harmonics | no |
Sags | no |
Transitory | no |
Test EN 50160 | no |
Starting currents | no |
Measurements in DC | yes |
K factor | Up to 25° |
Alarms | no |
Alarms logs | no |
Hourly tarifs | no |
Consumption costs | no |
Measurement campaign | Unlimited, up to SD completition |
Display data refres | 1 sec. |
Voltage (TRMS) | 1 input channel |
Current (TRMS) | 1 input channels |
Power | Active. Single phase and total |
Energy counters | kWh |
Harmonics analisys | no |
EN50160 analisys | no |
EN61724 analisys | no |
Test CEI 82-25 | yes: on network |
Transitional analisys | no |
CE conformity | 93/68/CEE (B.T. electrical materials); |
89/336/CEE e 2004/108/CE (EMC) | |
2006/95/CE – 72/23/CEE (LVD – Low voltages); | |
2002/95/CE (RoHS – Dangerous materials restrictions); | |
2002/96/CE e 2003/108/CE (WEEE/RAEE – Wasted electrical and electronics materials). | |
Safety | EN 61010-1 |
EMC | EN 61326 |
EN 61326/A1 | |
EN 61326/A2 | |
EN 61326/A3 | |
Temperature | IEC 60068-2-1 (working) |
IEC 60068-2-2 (storage) | |
Vibrations | IEC 60068-2-6 |
Umidity | IEC 60068-2-30 (umidity) |
Overload | IEC 60947-1 |
4NAN3N | NANOVIP/CUBE WITHOUT CLAMPS |
4NAN3 | NANOVIP/CUBE WITH 3xNANOFLEX CLAMP 400mm 3kA |
4NAN3A | NANOVIP/CUBE WITH 3xCLAMP CT 200A/1VAC |
4NAN3B | NANOVIP/CUBE WITH CLAMPS 3x200A + 3x3kA |
4NAN3C | NANOVIP/CUBE WITH CLAMPS 3x5A + 3x200A + 3x1000A |