Measurement
NANOVIP® BOX™
4G self-powered portable analyzer of the power quality of electrical networks
NanoVIP® BOX™ is an advanced and powerful Class S portable network analyzer, self-powered, developed for the professional analysis of consumption and power quality of the most complex electrical networks.
Can be used on single-phase, two-phase, three-phase systems (balanced or not), in low and medium voltage, self-powered from the measurement line and equipped with 4G communication which allows it to use the Elcontrol cloud, be driven via SMS or remotely controlled via the Elcontrol App .
NanoVIP® BOX™ is particularly suitable for those professionals who frequently carry out field checks and/or prolonged measurement campaigns; self-powering through the measurement line does not require the availability of a 110/220VAC power outlet which is almost never available in the field while 4G communication offers total control of the instrument from your office.
Autoalimentato con comunicazione 4G
- It does not require an external power supply because it is powered by the same voltage measurement line.
- Rechargeable buffer battery to guarantee operation for over 24h in the event of a voltage absence/dip.
- 4G communication for: control via SMS, connection to the Elcontrol Cloud and direct remote control from PC/App
- Download remote measurement campaigns
- Full coverage of EN50160 measurements and tests
- Can be used on systems: single-phase, two-phase, balanced three-phase with or without neutral, unbalanced three-phase with or without neutral
- Current and voltage harmonics for each phase and for the neutral up to the 50th (7th at 400Hz)
- Creation of long-term measurement campaigns (over 24 autonomously, unlimited if connected to the network)
- Free use of Elcontrol Cloud included
Applications
The NanoVIP BOX is a handy, compact and light tool aimed both at those who want to operate on their own systems and at professionals in the sector who need detailed and precise energy quality analyses; NanoVIP allows you to easily and intuitively:
- Keep the loads, consumption and related network costs under control
- Check the correct sizing of the systems during service
- Prevent the risks of overheating and lack of insulation due to high harmonic content
- Correctly solve power factor correction problems
- Identify and eliminate load peaks and power excesses in order to reduce the contractual electricity commitment
- Verify and evaluate the yields of UPS, with ac/dc measurements
- Measure even non-symmetrical signals for pwm controls on inverters
- Identify the presence of harmonics, interruptions, overloads or voltage dips potentially harmful to machinery and systems
- Intercept fluctuations and fast variations of current and voltage signals
- Measure inrush currents of electrical motors and machinery
Brochure NanoVIP® BOX™ 340 kb 44 downloads
Self powered Power Quality analyzer with 4G connectivity ...Standard | IEC61000-4-30 Class S |
Dimensions | 260x240x170mm |
Safety | 600V CAT III |
Protection | IP30 |
Weight | 435g. |
Display type | LCD dot matrix white backlight |
Languages | Inglese – Spagnolo – Italiano – Tedesco – Francese |
Communication | 4G + USB to PC |
Internal memory | 64kB |
External memory | Micro SD (min 4Gb included) |
Temperature | da -10 a +55 °C |
Umidity | Max 95% |
Power supply | Not required; self-powered |
Battery | 4 x AA MiMh 2100mAh |
Battery charge duration | >24h |
Monophase/biphase systems | Yes |
Threephase systems 4 wires (balanced/unbalanced) | Yes |
Threephase systems 3 wires (balanced/unbalanced) | Yes |
Energy and power analisys | V, I, P, Q, S, F, PF, THD(V)%, THD(I)%, cosj, j, peaks, min, max, averages, max. demand, ecc. |
Counters | kWh, kVArh, kVAh absorbed and generated |
Wave forms | V e I |
Harmonics | Up to 50th |
Sags | Dips, swells and interruptions |
Transients | Overcurrents and overvoltages |
Test EN 50160 | Yes |
inrush | Yes |
DC measures | Yes |
K factor | Up to 25th |
Alarms | Display |
Log alarms | 5 |
Tariffs | 4 |
Energy costs | Yes |
Surveys | unlimited up to SD availability (4Gb) |
Display data update | 1 sec. |
Suitable systems | Three phase (3 o 4 wires) biphase and monofase |
Networks | LV and MV |
Voltages (TRMS) | 4 channels (3 + neutral + 1 auxiliary) |
Currents (TRMS) | 5 channels |
Powers | Active, reactive and apparent. 3Ph and each phase |
Counters | kWh, kvarh, kVAh |
Harmonics | Up to 50th |
EN50160 | All events over 500mS |
Transients | Overvoltages, overcurrents and inrush |
CE | 93/68/CEE |
89/336/CEE e 2004/108/CE | |
2006/95/CE – 72/23/CEE | |
2002/95/CE | |
2002/96/CE e 2003/108/CE | |
Safety | EN 61010-1 |
EMC | EN 61326 |
EN 61326/A1 | |
EN 61326/A2 | |
EN 61326/A3 | |
Temperatures | IEC 60068-2-1 |
IEC 60068-2-2 | |
Vibrations | IEC 60068-2-6 |
Umidity | IEC 60068-2-30 (umidità) |
Overload | IEC 60947-1 |
4NANB | NANOVIP BOX WITH PINZE 3xTRUEFLEX CLAMP 600mm 3kA |
4NANBA | NANOVIP BOX WITH PINZE 3xCLAMP CT 200A/1VAC |
4NANBB | NANOVIP BOX WITH PINZE CLAMPS 3x200A + 3x3kA NANOFLEX |
4NANBD | NANOVIP BOX WITH PINZE CLAMPS 3x1000A |
4NANBN | NANOVIP BOX WITH PINZE 3xNANOFLEX CLAMP 600mm 3kA |
PART | Quantity | Standard/Option |
NanoVIP BOX | 1 | Standard |
Battery | 1 | Standard |
Voltage cables | 4 | Standard |
Crocodiles | 4 | Standard |
microSD min 4Gb | 1 | Standard |
microSD adapter | 1 | Standard |
Packaging | 1 | Standard |
Calibration certificate | 1 | Standard |
AC Current sensors | 3 or more | Option – according to kit |
DC Current sensors | 1 or more | Option – according to kit |